1-800-561-8187

information@ITM.com

Customer Reviews

Fluke Process Instruments RAYTMP150HR Infrared Linescanner, 3.5 – 4µm

Model: RAYTMP150HR

Fluke Process Instruments RAYTMP150HR Infrared Linescanner, 3.5 – 4µm-


Downloads: datasheet manual

Fluke Process Instruments RAYTMP150HR Infrared Linescanner, 3.5 – 4µm

Model: RAYTMP150HR

Infrared line scanner designed for use in highly demanding industrial environments provides accurate temperature images of moving objects. The multipoint measurement is achieved by a rotating optical system, which collects infrared radiation at up to 1024 points within a 90º field-of-view. The motorized mirror scans at rates up to 150 lines per second.

Infrared line scanner designed for use in highly demanding industrial environments provides accurate temperature images of moving objects. The multipoint measurement is achieved by a rotating optical system, which collects infrared radiation at up to 1024 points within a 90º field-of-view. The motorized mirror scans at rates up to 150 lines per second.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Fluke Process Instruments RAYTES150G5R0 Imaging System for Continuous Web Processes, 100 to 950°C (212 to 1742°F), 5µm, Standard Configuration-

Fluke Process Instruments RAYTES150G5R0 Imaging System for Continuous Web Processes, 100 to 950°C (212 to 1742°F), 5µm, Standard Configuration

Model: RAYTES150G5R0

Automated infrared linescanner inspection system for detecting, measuring, and classifying thermal features and defects occurring in continuous web processes.


Fluke Process RAYTES150LTR0 Imaging System for continuous web rocesses, 68 to 572°F, 3 to 5 µm, standard configuration-

Fluke Process RAYTES150LTR0 Imaging System for continuous web rocesses, 68 to 572°F, 3 to 5 µm, standard configuration

Model: RAYTES150LTR0

Automated infrared linescanner inspection system for detecting, measuring, and classifying thermal features and defects occurring in continuous web processes.


Fluke Process RAYTES150MTR0 Imaging System for continuous web processes, 212 to 1472°F, 3.9µm, standard configuration-

Fluke Process RAYTES150MTR0 Imaging System for continuous web processes, 212 to 1472°F, 3.9µm, standard configuration

Model: RAYTES150MTR0

Automated infrared linescanner inspection system for detecting, measuring, and classifying thermal features and defects occurring in continuous web processes.


Fluke Process RAYTES150P30R0 Imaging System for continuous web processes, 86 to 482°F, 3.43µm, standard configuration-

Fluke Process RAYTES150P30R0 Imaging System for continuous web processes, 86 to 482°F, 3.43µm, standard configuration

Model: RAYTES150P30R0

Automated infrared linescanner inspection system for detecting, measuring, and classifying thermal features and defects occurring in continuous web processes.


Fluke Process RAYTES150P31R0 Imaging System for continuous web processes, 212 to 662°F, 3.43µm, enhanced configuration-

Fluke Process RAYTES150P31R0 Imaging System for continuous web processes, 212 to 662°F, 3.43µm, enhanced configuration

Model: RAYTES150P31R0

Automated infrared linescanner inspection system for detecting, measuring, and classifying thermal features and defects occurring in continuous web processes.


Not what you're looking for? Let’s do a search and help you find what you need.


Fluke Process RAYTMP150HR Offers

Features

  • Real-time thermal imaging for continuous or discrete process
  • Up to 1024 measurement points per line
  • Fast scan rates up to 150 lines per second
  • Optical resolution up to 200:1
  • Built-in line laser for rapid alignment
  • On-board Ethernet TCP/IP communication
  • Wide choice of models and spectral responses

Raytek DataTemp® DP

The MP150 can be used in standalone mode, connected to a single PC or integrated into a comprehensive process control system using DataTemp® DP, an industrial Windows® software package, that provides remote configuration of the imager and real-time monitoring of the process. Utilizing the OPC Server functionality of the DataTemp DP software, the scanner becomes an integral part of any OPC compliant Distributed Control Interface (DCI) or Human Machine Interface (HMI) system. In all cases, the MP150 provides real-time monitoring and control capabilities.

Applications

In a paper mill, the paper leaves the fourdrinier machine and proceeds to wind over several steam-heated rollers to dry it before it is rolled up. If the drying is not complete, there will be streaks of water on the paper.

Raw material, such as steel billets and blooms, are manufactured in a steel mill and converted into bars and rod wires in a rod wire mill. The typical process temperatures are 550°C-900°C (1022°F-1652°F). The final product - rod wire, is in a coil form.

Fluke Process RAYTMP150HR Specifications

Spectral Response 3.5 – 4 µm
Temperature Range3 100 to 650°C
Accuracy ± 0.5% or ± 3°C (6°F)1
Repeatability ± 1°C (2°F)
Hot Spot Detection4 510:1
Measurement Resolution 170:1
Scan Motor MTBF: 40,000 h
Weight 7 kg (15 lb), incl. air purge
Click here for complete specifications on the Fluke Process RAYTMP150HR

What's included with the Fluke Process RAYTMP150HR

  • Adjustable Mounting Base
  • Power Supply, 240VAC / 24VDC, 1.3AM
  • Fiber Optic Converter Kit
  • Thermostat for Linescanner
  • Manual

Click on a category to view a selection of compatible accessories with the Fluke Process Instruments RAYTMP150HR Infrared Linescanner, 3.5 – 4µm.

Fluke Process A-CB-HT-M12-W04-07 Ethernet PoE Cable for the Thermalert 4.0 series, 356°F, 25' A-CB-HT-M12-W04-07
Compatible with the Thermalert 4.0 series of sensing heads, this Ethernet PoE cable is Teflon coated and withstands ambient temperatures up to 356°F (180°C). In addition, it comes with a four-pin male M12 D-coded connector assigned to the sensors rear female M12 connector, and the other end comes with an RJ45 snap-in connector.




Ask a question about Fluke Process Instruments RAYTMP150HR Infrared Linescanner, 3.5 – 4µm

Fluke Process RAYTMP150HR Offers

Features

  • Real-time thermal imaging for continuous or discrete process
  • Up to 1024 measurement points per line
  • Fast scan rates up to 150 lines per second
  • Optical resolution up to 200:1
  • Built-in line laser for rapid alignment
  • On-board Ethernet TCP/IP communication
  • Wide choice of models and spectral responses

Raytek DataTemp® DP

The MP150 can be used in standalone mode, connected to a single PC or integrated into a comprehensive process control system using DataTemp® DP, an industrial Windows® software package, that provides remote configuration of the imager and real-time monitoring of the process. Utilizing the OPC Server functionality of the DataTemp DP software, the scanner becomes an integral part of any OPC compliant Distributed Control Interface (DCI) or Human Machine Interface (HMI) system. In all cases, the MP150 provides real-time monitoring and control capabilities.

Applications

In a paper mill, the paper leaves the fourdrinier machine and proceeds to wind over several steam-heated rollers to dry it before it is rolled up. If the drying is not complete, there will be streaks of water on the paper.

Raw material, such as steel billets and blooms, are manufactured in a steel mill and converted into bars and rod wires in a rod wire mill. The typical process temperatures are 550°C-900°C (1022°F-1652°F). The final product - rod wire, is in a coil form.

Fluke Process RAYTMP150HR Specifications

Spectral Response 3.5 – 4 µm
Temperature Range3 100 to 650°C
Accuracy ± 0.5% or ± 3°C (6°F)1
Repeatability ± 1°C (2°F)
Hot Spot Detection4 510:1
Measurement Resolution 170:1
Scan Motor MTBF: 40,000 h
Weight 7 kg (15 lb), incl. air purge
Click here for complete specifications on the Fluke Process RAYTMP150HR

What's included with the Fluke Process RAYTMP150HR

  • Adjustable Mounting Base
  • Power Supply, 240VAC / 24VDC, 1.3AM
  • Fiber Optic Converter Kit
  • Thermostat for Linescanner
  • Manual

Click on a category to view a selection of compatible accessories with the Fluke Process Instruments RAYTMP150HR Infrared Linescanner, 3.5 – 4µm.

Fluke Process A-CB-HT-M12-W04-07 Ethernet PoE Cable for the Thermalert 4.0 series, 356°F, 25' A-CB-HT-M12-W04-07
Compatible with the Thermalert 4.0 series of sensing heads, this Ethernet PoE cable is Teflon coated and withstands ambient temperatures up to 356°F (180°C). In addition, it comes with a four-pin male M12 D-coded connector assigned to the sensors rear female M12 connector, and the other end comes with an RJ45 snap-in connector.




Ask a question about Fluke Process Instruments RAYTMP150HR Infrared Linescanner, 3.5 – 4µm